Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_HeatPumps_Compressors_Validation_ReciprocatingCompressor",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.399/2.399, allocations: 248.5 MB / 261 MB, free: 6.043 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002134/0.002133, allocations: 182.4 kB / 320.4 MB, free: 15.35 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.983/1.983, allocations: 205.2 MB / 0.571 GB, free: 11.79 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001146/0.001146, allocations: 97.75 kB / 0.6754 GB, free: 0.8828 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 4.291e-05/4.316e-05, allocations: 4 kB / 0.7869 GB, free: 97.8 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2128/0.2129, allocations: 106.3 MB / 0.8907 GB, free: 7.457 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.8661/1.079, allocations: 138.6 MB / 1.026 GB, free: 12.38 MB / 0.6511 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003428/1.079, allocations: 86.02 kB / 1.026 GB, free: 12.34 MB / 0.6511 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ReciprocatingCompressor$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor Notification: Performance of FrontEnd: time 0.02463/1.104, allocations: 5.424 MB / 1.031 GB, free: 7.715 MB / 0.6511 GB