Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_Geothermal_Borefields_Validation_ConstantHeatInjection_100Boreholes",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.202/2.202, allocations: 248.5 MB / 261 MB, free: 6.082 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001499/0.001498, allocations: 175 kB / 320.4 MB, free: 15.35 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.906/1.906, allocations: 205.2 MB / 0.571 GB, free: 11.83 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001096/0.001096, allocations: 98.05 kB / 0.6754 GB, free: 0.9219 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.781e-05/3.784e-05, allocations: 4 kB / 0.7869 GB, free: 97.83 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1942/0.1943, allocations: 106.2 MB / 0.8907 GB, free: 7.484 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.998/2.192, allocations: 0.4941 GB / 1.385 GB, free: 204.1 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003081/2.192, allocations: 101.8 kB / 1.385 GB, free: 204 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Streams.mo:212:5-212:61:writable] Warning: Unused input variable nrow in function .Modelica.Utilities.Streams.readRealMatrix. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Streams.mo:213:5-213:64:writable] Warning: Unused input variable ncol in function .Modelica.Utilities.Streams.readRealMatrix. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Geothermal/Borefields/Validation/ConstantHeatInjection_100Boreholes.mo:51:3-63:73:writable] Error: component hea contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes Notification: Performance of FrontEnd: time 25.36/27.56, allocations: 4.267 GB / 5.652 GB, free: 60.29 MB / 0.9794 GB