Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_Chillers_Validation_Carnot_TEva_reverseFlow",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.412/2.412, allocations: 248.5 MB / 261.1 MB, free: 5.973 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001438/0.001438, allocations: 180.7 kB / 320.4 MB, free: 15.34 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.907/1.907, allocations: 205.2 MB / 0.571 GB, free: 11.75 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00116/0.00116, allocations: 99.73 kB / 0.6754 GB, free: 0.8477 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.12e-05/3.124e-05, allocations: 4 kB / 0.7869 GB, free: 97.81 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2069/0.2069, allocations: 106.3 MB / 0.8907 GB, free: 7.457 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.831/2.038, allocations: 414.6 MB / 1.296 GB, free: 260 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003134/2.038, allocations: 89.52 kB / 1.296 GB, free: 260 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Chillers/Validation/Carnot_TEva_reverseFlow.mo:22:3-37:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow Notification: Performance of FrontEnd: time 0.2636/2.302, allocations: 82 MB / 1.376 GB, free: 225.8 MB / 0.8698 GB