Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented,fileNamePrefix="Buildings_7_0_0_Buildings_Electrical_DC_Sources_Examples_PVSimpleOriented",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.226/2.226, allocations: 248.5 MB / 261 MB, free: 5.977 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001664/0.001664, allocations: 185.8 kB / 320.4 MB, free: 15.34 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.95/1.95, allocations: 205.2 MB / 0.571 GB, free: 11.73 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001141/0.00114, allocations: 98.36 kB / 0.6754 GB, free: 0.8164 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.837e-05/3.848e-05, allocations: 4 kB / 0.7869 GB, free: 97.8 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2/0.2001, allocations: 106.3 MB / 0.8907 GB, free: 7.453 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.141/7.341, allocations: 2.224 GB / 3.115 GB, free: 115.4 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003105/7.342, allocations: 95.62 kB / 3.115 GB, free: 115.4 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented Notification: Performance of FrontEnd: time 0.05042/7.392, allocations: 12.34 MB / 3.127 GB, free: 104.9 MB / 0.8698 GB