Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel,fileNamePrefix="Buildings_7_0_0_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_PumpParallel",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.193/2.193, allocations: 248.5 MB / 261 MB, free: 6.051 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001553/0.001553, allocations: 180.1 kB / 320.4 MB, free: 15.34 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.042/2.042, allocations: 205.2 MB / 0.571 GB, free: 11.75 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001043/0.001043, allocations: 92.67 kB / 0.6754 GB, free: 0.8477 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.736e-05/3.751e-05, allocations: 4 kB / 0.7869 GB, free: 97.8 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2079/0.2079, allocations: 106.2 MB / 0.8907 GB, free: 7.469 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.938/2.146, allocations: 440.9 MB / 1.321 GB, free: 251.2 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003264/2.147, allocations: 100.7 kB / 1.321 GB, free: 251.2 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Equipment/BaseClasses/PartialPumpParallel.mo:105:11-105:18:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel Notification: Performance of FrontEnd: time 1.746/3.893, allocations: 346.5 MB / 1.66 GB, free: 209.4 MB / 0.8698 GB