Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary,fileNamePrefix="Buildings_7_0_0_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.25/2.25, allocations: 248.5 MB / 261.1 MB, free: 6.055 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001469/0.001468, allocations: 184.6 kB / 320.4 MB, free: 15.34 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.976/1.976, allocations: 205.2 MB / 0.571 GB, free: 11.79 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001176/0.001176, allocations: 98.09 kB / 0.6754 GB, free: 0.8828 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 4.068e-05/4.097e-05, allocations: 4 kB / 0.7869 GB, free: 97.79 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2227/0.2228, allocations: 106.2 MB / 0.8907 GB, free: 7.445 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 2.092/2.315, allocations: 0.5012 GB / 1.392 GB, free: 197.1 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003845/2.315, allocations: 112.3 kB / 1.392 GB, free: 197.1 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Equipment/IntegratedPrimarySecondary.mo:121:11-121:21:writable] Error: Type mismatch in binding pressure = Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure({0, 0}, {0, 0}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[2] V_flow; Real(min = 0.0, displayUnit = "Pa", quantity = "Pressure", unit = "Pa")[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure Integer[2] V_flow; Integer[2] dp; end Buildings.Fluid.Movers.BaseClasses.Characteristics.flowParameters$intWSEPriSec1$perPum$pressure;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary Notification: Performance of FrontEnd: time 11.95/14.26, allocations: 2.321 GB / 3.713 GB, free: 112 kB / 0.9948 GB