Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow,fileNamePrefix="Buildings_6_0_0_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_OnlyExteriorWallWithWindow",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.085/4.085, allocations: 432.6 MB / 445.2 MB, free: 15.82 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 3.814e-05/3.828e-05, allocations: 4.172 kB / 0.5383 GB, free: 10.29 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2466/0.2467, allocations: 98.73 MB / 0.6347 GB, free: 1.883 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.325/7.572, allocations: 2.327 GB / 2.961 GB, free: 81.25 MB / 0.8386 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002926/7.572, allocations: 97.56 kB / 2.962 GB, free: 81.2 MB / 0.8386 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow Notification: Performance of FrontEnd: time 2.325/9.897, allocations: 423 MB / 3.375 GB, free: 6.551 MB / 0.8386 GB