Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.NaturalConvection.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.NaturalConvection,fileNamePrefix="Buildings_6_0_0_Buildings_ThermalZones_Detailed_Examples_FFD_Tutorial_NaturalConvection",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4/4, allocations: 432.6 MB / 445.2 MB, free: 15.82 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 3.299e-05/3.32e-05, allocations: 4.031 kB / 0.5383 GB, free: 10.3 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2313/0.2314, allocations: 98.73 MB / 0.6347 GB, free: 1.879 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.242/7.473, allocations: 2.324 GB / 2.959 GB, free: 36.72 MB / 0.8386 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003497/7.474, allocations: 104.5 kB / 2.959 GB, free: 36.66 MB / 0.8386 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:248:11-248:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.NaturalConvection Notification: Performance of FrontEnd: time 1.103/8.577, allocations: 140.7 MB / 3.096 GB, free: 238.9 MB / 0.8386 GB