Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.BaseClasses.Examples.InfraredRadiationGainDistribution.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.BaseClasses.Examples.InfraredRadiationGainDistribution,fileNamePrefix="Buildings_6_0_0_Buildings_ThermalZones_Detailed_BaseClasses_Examples_InfraredRadiationGainDistribution",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.252/4.252, allocations: 432.6 MB / 445.2 MB, free: 15.75 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 4.796e-05/4.843e-05, allocations: 4.969 kB / 0.5383 GB, free: 10.28 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2463/0.2464, allocations: 98.72 MB / 0.6347 GB, free: 1.918 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.2707/0.5171, allocations: 140.6 MB / 0.772 GB, free: 5.09 MB / 0.6511 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004028/0.5176, allocations: 91.95 kB / 0.7721 GB, free: 5 MB / 0.6511 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/ThermalZones/Detailed/BaseClasses/Examples/InfraredRadiationGainDistribution.mo:14:11-14:36:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.BaseClasses.Examples.InfraredRadiationGainDistribution Notification: Performance of FrontEnd: time 0.9034/1.421, allocations: 51.52 MB / 0.8224 GB, free: 117.1 MB / 0.6511 GB