Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.Sandbox.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.Validation.Sandbox,fileNamePrefix="Buildings_6_0_0_Buildings_Fluid_Geothermal_Borefields_Validation_Sandbox",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.083/4.083, allocations: 432.6 MB / 445.2 MB, free: 15.73 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 3.62e-05/3.64e-05, allocations: 4.75 kB / 0.5383 GB, free: 10.3 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2148/0.2148, allocations: 98.73 MB / 0.6347 GB, free: 1.883 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.988/2.202, allocations: 499.3 MB / 1.122 GB, free: 222.2 MB / 0.8386 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003209/2.203, allocations: 102.8 kB / 1.122 GB, free: 222.2 MB / 0.8386 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2346:7-2347:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$sandBoxMea.getDerTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$sandBoxMea.getTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$sandBoxMea.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$sandBoxMea.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Geothermal/Borefields/Validation/Sandbox.mo:20:40-21:14:writable] Error: Component borHol.borFieDat of variability PARAM has binding borFieDat of higher variability VAR. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.Validation.Sandbox Notification: Performance of FrontEnd: time 0.1355/2.338, allocations: 38.61 MB / 1.16 GB, free: 217.7 MB / 0.8386 GB