Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Examples.ScalableBenchmarks.BuildingVAV.ThermalZones.Validation.ThermalZone.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Examples.ScalableBenchmarks.BuildingVAV.ThermalZones.Validation.ThermalZone,fileNamePrefix="Buildings_6_0_0_Buildings_Examples_ScalableBenchmarks_BuildingVAV_ThermalZones_Validation_ThermalZone",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 4.162/4.162, allocations: 432.6 MB / 445.2 MB, free: 15.75 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 3.707e-05/3.722e-05, allocations: 4.547 kB / 0.5383 GB, free: 10.27 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2317/0.2318, allocations: 98.73 MB / 0.6347 GB, free: 1.918 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.225/7.457, allocations: 2.357 GB / 2.992 GB, free: 51.1 MB / 0.8386 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003024/7.457, allocations: 98.61 kB / 2.992 GB, free: 51.05 MB / 0.8386 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/Outside.mo:28:3-31:49:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource.mo:38:3-40:49:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg", final quantity = Medium.substanceNames) "Needed to connect to conditional connector" second element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg") "Needed to connect to conditional connector" Error: Error occurred while flattening model Buildings.Examples.ScalableBenchmarks.BuildingVAV.ThermalZones.Validation.ThermalZone Notification: Performance of FrontEnd: time 1.602/9.059, allocations: 262.2 MB / 3.248 GB, free: 137.2 MB / 0.8386 GB