Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,fileNamePrefix="Buildings_5_0_1_Buildings_Fluid_Chillers_Validation_Carnot_TEva_reverseFlow",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 3.856/3.856, allocations: 403.3 MB / 415.4 MB, free: 13.02 MB / 330.7 MB Notification: Performance of FrontEnd - loaded program: time 3.935e-05/3.976e-05, allocations: 11.94 kB / 0.4991 GB, free: 13.36 MB / 426.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6165/0.6165, allocations: 92.68 MB / 0.5896 GB, free: 14.47 MB / 490.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.265/1.881, allocations: 397.5 MB / 0.9778 GB, free: 8.734 MB / 0.698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003535/1.882, allocations: 88.83 kB / 0.9779 GB, free: 8.691 MB / 0.698 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Fluid/Chillers/Validation/Carnot_TEva_reverseFlow.mo:22:3-37:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow Notification: Performance of FrontEnd: time 0.2776/2.159, allocations: 81.17 MB / 1.057 GB, free: 14.77 MB / 0.7761 GB