Running command: "" <> buildModelFMU(Buildings.Experimental.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall,fileNamePrefix="Buildings_5_0_1_Buildings_Experimental_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(Buildings): time 3.841/3.841, allocations: 403.3 MB / 415.4 MB, free: 13 MB / 330.7 MB Notification: Performance of FrontEnd - loaded program: time 3.727e-05/3.745e-05, allocations: 4 kB / 0.4991 GB, free: 13.38 MB / 426.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.634/0.6341, allocations: 92.68 MB / 0.5896 GB, free: 14.41 MB / 490.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 8.454/9.088, allocations: 2.561 GB / 3.151 GB, free: 189.5 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003515/9.089, allocations: 92.19 kB / 3.151 GB, free: 189.5 MB / 0.7761 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2346:7-2347:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$larOff$loa.getDerTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$larOff$loa.getTableValue. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$larOff$loa.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$larOff$loa.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Experimental/DistrictHeatingCooling/SubStations/VaporCompression/HeatingCoolingHotwaterTimeSeries_dT.mo:235:3-247:75:writable] Error: Variable larOff.chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$larOff$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Experimental.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall Notification: Performance of FrontEnd: time 0.6612/9.75, allocations: 212.3 MB / 3.358 GB, free: 72.93 MB / 0.7761 GB