Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr AixLib_AixLib.Systems.HydraulicModules.Example.Pump.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo", uses=false) Using package SDF with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo) Using package Modelica_DeviceDrivers with version 2.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package AixLib with version 1.3.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo) Running command: "" <> buildModelFMU(AixLib.Systems.HydraulicModules.Example.Pump,fileNamePrefix="AixLib_AixLib_Systems_HydraulicModules_Example_Pump",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(AixLib.Systems.HydraulicModules.Example.Pump,fileNamePrefix="AixLib_AixLib_Systems_HydraulicModules_Example_Pump",fmuType="me",version="2.0",platforms={"static"}) [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/BoundaryConditions/InternalGains/Examples/InternalGains/Lights.mo:27:20-27:398:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/BoundaryConditions/InternalGains/Examples/InternalGains/Machines.mo:31:20-31:400:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_Cleanergy_C9G.mo:36:34-36:594:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:588:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/CHP/CHPDataSimple/CHP_XRGI_9kWel.mo:25:34-25:3852:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_NE_SE_SW_NW_Hor.mo:5:35-5:324:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_Hor.mo:5:35-5:320:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/DataBase/Weather/SurfaceOrientation/SurfaceOrientationData_N_E_S_W_RoofN_Roof_S.mo:5:35-5:362:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6228:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:6853:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:8435:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:9369:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:11505:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Obsolete/YearIndependent/FastHVAC/Components/HeatExchangers/RadiatorMultiLayer.mo:265:34-265:12875:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:2066:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/DryAir/InfiltrationRate_DIN12831.mo:20:192-20:4252:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/ThermalZones/HighOrder/Components/Examples/DryAir/DryAir_test.mo:71:18-71:405:writable] Warning: Lexer treating \ as \\, since \ is not a valid Modelica escape sequence. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/package.mo): time 2.182/2.182, allocations: 264.9 MB / 277.5 MB, free: 4.211 MB / 218.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001083/0.001083, allocations: 169 kB / 335 MB, free: 11.34 MB / 282.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.646/1.646, allocations: 221.3 MB / 0.5993 GB, free: 10.09 MB / 458.8 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009773/0.0009774, allocations: 90.95 kB / 0.7046 GB, free: 51.38 MB / 0.5418 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_DeviceDrivers 2.1.1/package.mo): time 0.05891/0.05891, allocations: 11.88 MB / 0.8215 GB, free: 428 kB / 0.573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo:9:42-9:258:writable] Notification: This is an open source dummy package of a commercial library. If you want it to be supported, you will need to add an implemention on our github repository: https://github.com/Modelica-OpenVendorSpecificLibraries. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SDF master/package.mo): time 0.0004186/0.0004188, allocations: 23.89 kB / 0.9296 GB, free: 1.57 MB / 0.6824 GB Warning: Requested package SDF of version 0.4.2, but this package was already loaded with version 0.0.0. You might experience problems if these versions are incompatible. Notification: Performance of FrontEnd - loaded program: time 5.235e-05/5.237e-05, allocations: 9.812 kB / 1.047 GB, free: 250.9 MB / 0.7293 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2496/0.2497, allocations: 110.2 MB / 1.155 GB, free: 141 MB / 0.7293 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.279/1.529, allocations: 464.5 MB / 1.608 GB, free: 13.36 MB / 0.9168 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002596/1.529, allocations: 95.89 kB / 1.608 GB, free: 13.31 MB / 0.9168 GB Notification: Performance of FrontEnd - DAE generated: time 9.079/10.61, allocations: 2.092 GB / 3.7 GB, free: 62.38 MB / 1.026 GB Notification: Performance of FrontEnd: time 2.214e-06/10.61, allocations: 0 / 3.7 GB, free: 62.38 MB / 1.026 GB Notification: Performance of Transformations before backend: time 0.001094/10.61, allocations: 149.2 kB / 3.7 GB, free: 62.35 MB / 1.026 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 912 * Number of variables: 912 Notification: Performance of Generate backend data structure: time 0.02011/10.63, allocations: 5.397 MB / 3.706 GB, free: 59.81 MB / 1.026 GB Notification: Performance of prepare preOptimizeDAE: time 5.409e-05/10.63, allocations: 11.44 kB / 3.706 GB, free: 59.81 MB / 1.026 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.002189/10.63, allocations: 479.5 kB / 3.706 GB, free: 59.75 MB / 1.026 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.005085/10.64, allocations: 0.7667 MB / 3.707 GB, free: 59.4 MB / 1.026 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.03674/10.67, allocations: 13.17 MB / 3.72 GB, free: 58.33 MB / 1.026 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0003369/10.67, allocations: 286.5 kB / 3.72 GB, free: 58.32 MB / 1.026 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.001542/10.68, allocations: 388.8 kB / 3.72 GB, free: 58.31 MB / 1.026 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.01057/10.69, allocations: 4.279 MB / 3.725 GB, free: 57.81 MB / 1.026 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0001188/10.69, allocations: 6.625 kB / 3.725 GB, free: 57.81 MB / 1.026 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0005481/10.69, allocations: 148.2 kB / 3.725 GB, free: 57.81 MB / 1.026 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0001537/10.69, allocations: 141.5 kB / 3.725 GB, free: 57.8 MB / 1.026 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.00716/10.69, allocations: 3.201 MB / 3.728 GB, free: 57.77 MB / 1.026 GB Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.0376/10.73, allocations: 24.78 MB / 3.752 GB, free: 47.09 MB / 1.026 GB Notification: Performance of preOpt comSubExp (simulation): time 0.003984/10.74, allocations: 2.149 MB / 3.754 GB, free: 47.03 MB / 1.026 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.002011/10.74, allocations: 1.206 MB / 3.756 GB, free: 47.02 MB / 1.026 GB Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt evalFunc (simulation): time 0.01671/10.76, allocations: 10.76 MB / 3.766 GB, free: 41.24 MB / 1.026 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 4.041e-05/10.76, allocations: 56.97 kB / 3.766 GB, free: 41.2 MB / 1.026 GB Notification: Performance of preOpt simplifyInStream (simulation): time 0.003431/10.76, allocations: 335.2 kB / 3.766 GB, free: 41.09 MB / 1.026 GB Notification: Performance of pre-optimization done (n=215): time 7.143e-06/10.76, allocations: 0 / 3.766 GB, free: 41.09 MB / 1.026 GB Notification: Performance of matching and sorting (n=215): time 0.007415/10.77, allocations: 2.977 MB / 3.769 GB, free: 40.66 MB / 1.026 GB Notification: Performance of inlineWhenForInitialization (initialization): time 3.98e-05/10.77, allocations: 74.94 kB / 3.769 GB, free: 40.59 MB / 1.026 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.009101/10.78, allocations: 4.793 MB / 3.774 GB, free: 40.21 MB / 1.026 GB Notification: Performance of collectPreVariables (initialization): time 0.0007383/10.78, allocations: 71.86 kB / 3.774 GB, free: 40.14 MB / 1.026 GB Notification: Performance of collectInitialEqns (initialization): time 0.002139/10.78, allocations: 2.575 MB / 3.777 GB, free: 38.12 MB / 1.026 GB Notification: Performance of collectInitialBindings (initialization): time 0.001083/10.78, allocations: 0.7549 MB / 3.777 GB, free: 37.54 MB / 1.026 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.0001606/10.78, allocations: 56.95 kB / 3.777 GB, free: 37.49 MB / 1.026 GB Notification: Performance of setup shared object (initialization): time 0.0001656/10.78, allocations: 416.4 kB / 3.778 GB, free: 37.14 MB / 1.026 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.001659/10.78, allocations: 0.9919 MB / 3.779 GB, free: 36.7 MB / 1.026 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.002029/10.78, allocations: 1.802 MB / 3.781 GB, free: 35.25 MB / 1.026 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.001992/10.79, allocations: 1.32 MB / 3.782 GB, free: 34.63 MB / 1.026 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 1.588e-05/10.79, allocations: 11.52 kB / 3.782 GB, free: 34.63 MB / 1.026 GB Notification: Performance of matching and sorting (n=358) (initialization): time 0.009024/10.79, allocations: 3.937 MB / 3.786 GB, free: 32.91 MB / 1.026 GB Notification: Performance of prepare postOptimizeDAE: time 0.002396/10.8, allocations: 10.43 MB / 3.796 GB, free: 21.83 MB / 1.026 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 7.14e-05/10.8, allocations: 26.16 kB / 3.796 GB, free: 21.83 MB / 1.026 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.003481/10.8, allocations: 0.8007 MB / 3.797 GB, free: 21.58 MB / 1.026 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.00239/10.8, allocations: 0.5849 MB / 3.797 GB, free: 21.52 MB / 1.026 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.005613/10.81, allocations: 7.375 MB / 3.804 GB, free: 14.71 MB / 1.026 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.006842/10.82, allocations: 332.7 kB / 3.805 GB, free: 14.62 MB / 1.026 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0009813/10.82, allocations: 165.6 kB / 3.805 GB, free: 14.59 MB / 1.026 GB Notification: Performance of prepare postOptimizeDAE: time 1.937e-05/10.82, allocations: 5.156 kB / 3.805 GB, free: 14.59 MB / 1.026 GB Notification: Performance of postOpt replaceHomotopyWithSimplified (initialization): time 0.007987/10.82, allocations: 3.65 MB / 3.809 GB, free: 13.04 MB / 1.026 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 6.449e-05/10.82, allocations: 35.2 kB / 3.809 GB, free: 13.04 MB / 1.026 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.003484/10.83, allocations: 0.9836 MB / 3.81 GB, free: 12.71 MB / 1.026 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.002026/10.83, allocations: 0.5699 MB / 3.81 GB, free: 12.66 MB / 1.026 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.01192/10.84, allocations: 11.44 MB / 3.821 GB, free: 19.36 MB / 1.042 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.006353/10.85, allocations: 317.8 kB / 3.822 GB, free: 19.28 MB / 1.042 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0008351/10.85, allocations: 161.2 kB / 3.822 GB, free: 19.25 MB / 1.042 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 98 * Number of states: 0 () * Number of discrete variables: 0 () * Number of discrete states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (311): * Single equations (assignments): 297 * Array equations: 1 * Algorithm blocks: 0 * Record equations: 6 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 7 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 3 {(1,100.0%) 2,(1,100.0%) 2,(1,100.0%) 2} * Non-linear torn systems: 4 {1 5,1 5,1 5,1 11} Notification: Performance of prepare postOptimizeDAE: time 0.001034/10.85, allocations: 278.1 kB / 3.822 GB, free: 19.01 MB / 1.042 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.00216/10.85, allocations: 0.4894 MB / 3.822 GB, free: 18.75 MB / 1.042 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01074/10.86, allocations: 4.268 MB / 3.827 GB, free: 17.04 MB / 1.042 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 6.394e-05/10.86, allocations: 39.88 kB / 3.827 GB, free: 17.04 MB / 1.042 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.264e-05/10.86, allocations: 3.953 kB / 3.827 GB, free: 17.03 MB / 1.042 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.005454/10.87, allocations: 3.072 MB / 3.83 GB, free: 15.68 MB / 1.042 GB Warning: The model contains alias variables with conflicting start and/or nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.02215/10.89, allocations: 9.979 MB / 3.839 GB, free: 10.73 MB / 1.042 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 3.469e-05/10.89, allocations: 7.875 kB / 3.839 GB, free: 10.73 MB / 1.042 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.001605/10.89, allocations: 378.8 kB / 3.84 GB, free: 10.71 MB / 1.042 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.002543/10.89, allocations: 0.6178 MB / 3.84 GB, free: 10.5 MB / 1.042 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0002462/10.9, allocations: 88.8 kB / 3.84 GB, free: 10.45 MB / 1.042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.007562/10.9, allocations: 7.009 MB / 3.847 GB, free: 3.867 MB / 1.042 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 6.843e-06/10.9, allocations: 8.109 kB / 3.847 GB, free: 3.863 MB / 1.042 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.01281/10.92, allocations: 5.411 MB / 3.853 GB, free: 1.223 MB / 1.042 GB Notification: Performance of postOpt removeConstants (simulation): time 0.004947/10.92, allocations: 1.221 MB / 3.854 GB, free: 392 kB / 1.042 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.002032/10.92, allocations: 61.28 kB / 3.854 GB, free: 348 kB / 1.042 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.004476/10.93, allocations: 288.3 kB / 3.854 GB, free: 268 kB / 1.042 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0003465/10.93, allocations: 173.9 kB / 3.854 GB, free: 240 kB / 1.042 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0003327/10.93, allocations: 124.1 kB / 3.854 GB, free: 220 kB / 1.042 GB Notification: Performance of sorting global known variables: time 0.01006/10.94, allocations: 3.846 MB / 3.858 GB, free: 15.22 MB / 1.057 GB Notification: Performance of sort global known variables: time 3.31e-07/10.94, allocations: 0 / 3.858 GB, free: 15.22 MB / 1.057 GB Notification: Performance of remove unused functions: time 0.01937/10.96, allocations: 3.448 MB / 3.862 GB, free: 14.37 MB / 1.057 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 5 * Number of states: 26 (Unmixed.senT_a1.T,Unmixed.senT_a2.T,Unmixed.senT_b1.T,Unmixed.senT_b2.T,Unmixed.PT1_b2.y,Unmixed.PT1_b1.y,Unmixed.PT1_a1.y,Unmixed.PT1_a2.y,Unmixed.PumpInterface.pump.vol.dynBal.U,Unmixed.PumpInterface.pump.filter.s[1],Unmixed.PumpInterface.pump.filter.s[2],Unmixed.pipe1.plugFlowPipe.del.x,Unmixed.pipe1.plugFlowPipe.timDel.x,Unmixed.pipe1.plugFlowPipe.vol_b.dynBal.U,Unmixed.pipe1.plugFlowPipe.vol_a.dynBal.U,Unmixed.pipe1.Insulation.CylindricLoad1.heatCapacitor.T,Unmixed.pipe2.plugFlowPipe.del.x,Unmixed.pipe2.plugFlowPipe.timDel.x,Unmixed.pipe2.plugFlowPipe.vol_b.dynBal.U,Unmixed.pipe2.plugFlowPipe.vol_a.dynBal.U,Unmixed.pipe2.Insulation.CylindricLoad1.heatCapacitor.T,Unmixed.pipe3.plugFlowPipe.del.x,Unmixed.pipe3.plugFlowPipe.timDel.x,Unmixed.pipe3.plugFlowPipe.vol_b.dynBal.U,Unmixed.pipe3.plugFlowPipe.vol_a.dynBal.U,Unmixed.pipe3.Insulation.CylindricLoad1.heatCapacitor.T) * Number of discrete variables: 0 () * Number of discrete states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (226): * Single equations (assignments): 183 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 36 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 7 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 3 {(1,100.0%) 2,(1,100.0%) 2,(1,100.0%) 2} * Non-linear torn systems: 4 {1 7,1 7,1 7,1 11} Notification: Performance of Backend phase and start with SimCode phase: time 0.02161/10.98, allocations: 9.32 MB / 3.871 GB, free: 6.031 MB / 1.057 GB Notification: Performance of simCode: created initialization part: time 0.01145/10.99, allocations: 5.801 MB / 3.876 GB, free: 308 kB / 1.057 GB Notification: Performance of simCode: created event and clocks part: time 1.155e-05/10.99, allocations: 4 kB / 3.876 GB, free: 304 kB / 1.057 GB Notification: Performance of simCode: created simulation system equations: time 0.003202/10.99, allocations: 1.944 MB / 3.878 GB, free: 14.36 MB / 1.073 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01522/11.01, allocations: 2.642 MB / 3.881 GB, free: 12.46 MB / 1.073 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.02967/11.04, allocations: 9.854 MB / 3.89 GB, free: 3.594 MB / 1.073 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.003086/11.04, allocations: 3.035 MB / 3.893 GB, free: 1.352 MB / 1.073 GB Notification: Performance of simCode: alias equations: time 0.009645/11.05, allocations: 1.722 MB / 3.895 GB, free: 268 kB / 1.073 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.8816/11.93, allocations: 2.385 MB / 3.897 GB, free: 101.9 MB / 1.073 GB Notification: Performance of SimCode: time 1.423e-06/11.93, allocations: 1.812 kB / 3.897 GB, free: 101.9 MB / 1.073 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.4062/12.34, allocations: 206.8 MB / 4.099 GB, free: 89.31 MB / 1.073 GB Notification: Performance of buildModelFMU: configured platform static using cached values: time 0.0001762/12.34, allocations: 211.3 kB / 4.1 GB, free: 89.09 MB / 1.073 GB Error: Error building simulator. Build log: clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:7: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1202:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[349] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[19] /* Unmixed.pipe3.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe3.plugFlowPipe.timDel.u) */, tmp18, tmp19, tmp20 ,&data->localData[0]->realVars[348] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1317:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[287] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[14] /* Unmixed.pipe2.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe2.plugFlowPipe.timDel.u) */, tmp21, tmp22, tmp23 ,&data->localData[0]->realVars[286] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1420:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[226] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[9] /* Unmixed.pipe1.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe1.plugFlowPipe.timDel.u) */, tmp24, tmp25, tmp26 ,&data->localData[0]->realVars[225] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1667:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[223] /* Unmixed.pipe1.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[384] /* Unmixed.port_a1.h_outflow variable */, data->localData[0]->realVars[261] /* Unmixed.pipe1.port_b.h_outflow variable */, data->localData[0]->realVars[8] /* Unmixed.pipe1.plugFlowPipe.del.x STATE(1,Unmixed.pipe1.plugFlowPipe.v) */, tmp27, tmp28, tmp29 ,&data->localData[0]->realVars[208] /* Unmixed.pipe1.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1792:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[284] /* Unmixed.pipe2.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[322] /* Unmixed.pipe2.port_a.h_outflow variable */, data->localData[0]->realVars[387] /* Unmixed.port_b1.h_outflow variable */, data->localData[0]->realVars[13] /* Unmixed.pipe2.plugFlowPipe.del.x STATE(1,Unmixed.pipe2.plugFlowPipe.v) */, tmp34, tmp35, tmp36 ,&data->localData[0]->realVars[270] /* Unmixed.pipe2.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:1917:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[346] /* Unmixed.pipe3.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[385] /* Unmixed.port_a2.h_outflow variable */, data->localData[0]->realVars[389] /* Unmixed.port_b2.h_outflow variable */, (0.5) * (data->localData[0]->realVars[18] /* Unmixed.pipe3.plugFlowPipe.del.x STATE(1,Unmixed.pipe3.plugFlowPipe.v) */), tmp41, tmp42, tmp43 ,&data->localData[0]->realVars[331] /* Unmixed.pipe3.plugFlowPipe.del.port_b.h_outflow variable */); ^ 8 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.h:3: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:4425:10: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_n == ((modelica_integer) 1))) ~~~^~~~~~~~~~~~~~~~~~~~~~~~~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:4425:10: note: remove extraneous parentheses around the comparison to silence this warning if((_n == ((modelica_integer) 1))) ~ ^ ~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:4425:10: note: use '=' to turn this equality comparison into an assignment if((_n == ((modelica_integer) 1))) ^~ = AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:5764:10: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_n == ((modelica_integer) 1))) ~~~^~~~~~~~~~~~~~~~~~~~~~~~~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:5764:10: note: remove extraneous parentheses around the comparison to silence this warning if((_n == ((modelica_integer) 1))) ~ ^ ~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:5764:10: note: use '=' to turn this equality comparison into an assignment if((_n == ((modelica_integer) 1))) ^~ = AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6087:10: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_n == ((modelica_integer) 1))) ~~~^~~~~~~~~~~~~~~~~~~~~~~~~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6087:10: note: remove extraneous parentheses around the comparison to silence this warning if((_n == ((modelica_integer) 1))) ~ ^ ~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6087:10: note: use '=' to turn this equality comparison into an assignment if((_n == ((modelica_integer) 1))) ^~ = AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6093:12: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_n == ((modelica_integer) 2))) ~~~^~~~~~~~~~~~~~~~~~~~~~~~~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6093:12: note: remove extraneous parentheses around the comparison to silence this warning if((_n == ((modelica_integer) 2))) ~ ^ ~ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.c:6093:12: note: use '=' to turn this equality comparison into an assignment if((_n == ((modelica_integer) 2))) ^~ = 6 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.c:4: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1558:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[223] /* Unmixed.pipe1.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[384] /* Unmixed.port_a1.h_outflow variable */, data->localData[0]->realVars[261] /* Unmixed.pipe1.port_b.h_outflow variable */, data->localData[0]->realVars[8] /* Unmixed.pipe1.plugFlowPipe.del.x STATE(1,Unmixed.pipe1.plugFlowPipe.v) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[208] /* Unmixed.pipe1.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1608:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[226] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[9] /* Unmixed.pipe1.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe1.plugFlowPipe.timDel.u) */, tmp3, tmp4, tmp5 ,&data->localData[0]->realVars[225] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1728:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[287] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[14] /* Unmixed.pipe2.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe2.plugFlowPipe.timDel.u) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[286] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1818:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[346] /* Unmixed.pipe3.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[385] /* Unmixed.port_a2.h_outflow variable */, data->localData[0]->realVars[389] /* Unmixed.port_b2.h_outflow variable */, (0.5) * (data->localData[0]->realVars[18] /* Unmixed.pipe3.plugFlowPipe.del.x STATE(1,Unmixed.pipe3.plugFlowPipe.v) */), tmp3, tmp4, tmp5 ,&data->localData[0]->realVars[331] /* Unmixed.pipe3.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:1868:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[349] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[19] /* Unmixed.pipe3.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe3.plugFlowPipe.timDel.u) */, tmp6, tmp7, tmp8 ,&data->localData[0]->realVars[348] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:2054:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[284] /* Unmixed.pipe2.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[322] /* Unmixed.pipe2.port_a.h_outflow variable */, data->localData[0]->realVars[387] /* Unmixed.port_b1.h_outflow variable */, data->localData[0]->realVars[13] /* Unmixed.pipe2.plugFlowPipe.del.x STATE(1,Unmixed.pipe2.plugFlowPipe.v) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[270] /* Unmixed.pipe2.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:21722:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[223] /* Unmixed.pipe1.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[384] /* Unmixed.port_a1.h_outflow variable */, data->localData[0]->realVars[261] /* Unmixed.pipe1.port_b.h_outflow variable */, data->localData[0]->realVars[8] /* Unmixed.pipe1.plugFlowPipe.del.x STATE(1,Unmixed.pipe1.plugFlowPipe.v) */, tmp75, tmp76, tmp77 ,&data->localData[0]->realVars[208] /* Unmixed.pipe1.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:21750:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[226] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[9] /* Unmixed.pipe1.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe1.plugFlowPipe.timDel.u) */, tmp78, tmp79, tmp80 ,&data->localData[0]->realVars[225] /* Unmixed.pipe1.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:21837:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[287] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[14] /* Unmixed.pipe2.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe2.plugFlowPipe.timDel.u) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[286] /* Unmixed.pipe2.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:21883:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[346] /* Unmixed.pipe3.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[385] /* Unmixed.port_a2.h_outflow variable */, data->localData[0]->realVars[389] /* Unmixed.port_b2.h_outflow variable */, (0.5) * (data->localData[0]->realVars[18] /* Unmixed.pipe3.plugFlowPipe.del.x STATE(1,Unmixed.pipe3.plugFlowPipe.v) */), tmp3, tmp4, tmp5 ,&data->localData[0]->realVars[331] /* Unmixed.pipe3.plugFlowPipe.del.port_b.h_outflow variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:21911:101: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[349] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_rev variable */ = spatialDistribution(data->localData[0]->timeValue, data->localData[0]->timeValue, data->localData[0]->realVars[19] /* Unmixed.pipe3.plugFlowPipe.timDel.x STATE(1,Unmixed.pipe3.plugFlowPipe.timDel.u) */, tmp6, tmp7, tmp8 ,&data->localData[0]->realVars[348] /* Unmixed.pipe3.plugFlowPipe.timDel.time_out_des variable */); ^ AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.c:22020:102: warning: implicit declaration of function 'spatialDistribution' is invalid in C99 [-Wimplicit-function-declaration] data->localData[0]->realVars[284] /* Unmixed.pipe2.plugFlowPipe.res.port_a.h_outflow variable */ = spatialDistribution(data->localData[0]->realVars[322] /* Unmixed.pipe2.port_a.h_outflow variable */, data->localData[0]->realVars[387] /* Unmixed.port_b1.h_outflow variable */, data->localData[0]->realVars[13] /* Unmixed.pipe2.plugFlowPipe.del.x STATE(1,Unmixed.pipe2.plugFlowPipe.v) */, tmp0, tmp1, tmp2 ,&data->localData[0]->realVars[270] /* Unmixed.pipe2.plugFlowPipe.del.port_b.h_outflow variable */); ^ 14 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.c:2: In file included from ./AixLib_AixLib_Systems_HydraulicModules_Example_Pump_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.c:1: In file included from ./simulation_data.h:39: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -DOMC_MINIMAL_RUNTIME=1 -DCMINPACK_NO_DLL=1 -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -c -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.c In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.c:9: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:111: ./gc/omc_gc.h:217:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:221:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ In file included from AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.c:54: ./fmi-export/fmu2_model_interface.c.inc:73:11: warning: enumeration value 'modelSlaveInitialized' not handled in switch [-Wswitch] switch (comp->state) ^ ./fmi-export/fmu2_model_interface.c.inc:162:16: warning: passing 'char **' to parameter of type 'const char **' discards qualifiers in nested pointer types [-Wincompatible-pointer-types-discards-qualifiers] GC_vasprintf(&str, msg, args); ^~~~ ./gc/../meta/../util/modelica_string.h:71:31: note: passing argument to parameter 'strp' here int GC_vasprintf(const char **strp, const char *fmt, va_list ap); ^ 4 warnings generated. mkdir -p ../binaries/linux64 clang -shared -o AixLib_AixLib_Systems_HydraulicModules_Example_Pump.so AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_functions.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_records.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_01exo.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_02nls.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_03lsy.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_04set.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_05evt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_06inz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_07dly.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_08bnd.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_09alg.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_10asr.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_11mix.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_12jac.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_13opt.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_14lnz.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_15syn.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_16dae.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_17inl.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_init_fmu.o AixLib_AixLib_Systems_HydraulicModules_Example_Pump_FMU.o -L"/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Systems/HydraulicModules/Example" -Wl,-Bstatic "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" "-L/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/x86_64-linux" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/x86_64-linux" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/linux64" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library/linux64" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/Library" -lModelicaExternalC -Wl,-Bdynamic -L'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -Wl,-rpath,'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -lSimulationRuntimeFMI -Wl,--no-as-needed -Wl,--disable-new-dtags -llapack -lblas -lm -lpthread -rdynamic -Wl,--no-undefined /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_2166': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x26fb): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_2175': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x2d63): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_2183': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x3386): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_2203': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x4101): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o: in function `AixLib_AixLib_Systems_HydraulicModules_Example_Pump_eqFunction_2212': AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x4603): undefined reference to `spatialDistribution' /usr/bin/ld: AixLib_AixLib_Systems_HydraulicModules_Example_Pump.o:AixLib_AixLib_Systems_HydraulicModules_Example_Pump.c:(.text+0x4b05): more undefined references to `spatialDistribution' follow clang: error: linker command failed with exit code 1 (use -v to see invocation) make: *** [Makefile:32: nozip] Error 1