OMSimulator --tempDir=temp_AixLib_AixLib_Fluid_Movers_Compressors_Validation_StaticHeatPumpBoundaries_SpecifiedModels_RefrigerantR410aScrollCompressorController_fmu --startTime=0 --stopTime=16.9999 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Fluid_Movers_Compressors_Validation_StaticHeatPumpBoundaries_SpecifiedModels_RefrigerantR410aScrollCompressorController.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_AixLib_AixLib_Fluid_Movers_Compressors_Validation_StaticHeatPumpBoundaries_SpecifiedModels_RefrigerantR410aScrollCompressorController_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Compressors.Validation.StaticHeatPumpBoundaries.SpecifiedModels.RefrigerantR410aScrollCompressorController/temp_AixLib_AixLib_Fluid_Movers_Compressors_Validation_StaticHeatPumpBoundaries_SpecifiedModels_RefrigerantR410aScrollCompressorController_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Compressors.Validation.StaticHeatPumpBoundaries.SpecifiedModels.RefrigerantR410aScrollCompressorController" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Compressors.Validation.StaticHeatPumpBoundaries.SpecifiedModels.RefrigerantR410aScrollCompressorController/temp_AixLib_AixLib_Fluid_Movers_Compressors_Validation_StaticHeatPumpBoundaries_SpecifiedModels_RefrigerantR410aScrollCompressorController_fmu/model-ls34gyvp" warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Fluid/Movers/Compressors/Validation/StaticHeatPumpBoundaries/BaseModelStaticHeatPumpController.mo:411: The following assertion has been violated at time 0.000000 con.m_flow >= -0.0 and con.m_flow <= 0.0 assert | warning | Variable violating min/max constraint: -0.0 <= con.m_flow <= 0.0, has value: 0.0232748 info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.fmu.inpDat.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.fmu.inpDat.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.fmu.modCom.modSen.senPre[1].instanceName will not be stored in the result file, because the signal type is not supported warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2-development/Fluid/Movers/Compressors/BaseClasses/PartialCompression.mo:317: The following assertion has been violated at time 5.323201 modCom.modCon.curManVar[1] <= modCom.modCom[1].comPro.rotSpeMax assert | warning | Rotational speed is greater than maximum | | | | rotational speed allowed! Please check boundary condtions!