startTime=0 stopTime=1200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.48 Regular simulation: ./ThermoPower_ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_E -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0296972s reading init.xml | | | | | | 0.00287098s reading info.xml | | | | | | 0.000503054s [ 0.0%] pre-initialization | | | | | | 0.216777s [ 12.2%] initialization | | | | | | 0.00020261s [ 0.0%] steps | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000732815s [ 0.0%] event-handling | | | | | | 0.0233818s [ 1.3%] overhead | | | | | | 1.53967s [ 86.4%] simulation | | | | | | 1.78127s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 182 steps taken | | | | | | 240 calls of functionODE | | | | | | 36 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 0 convergence test failures | | | | | | 0.273884s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.