startTime=0 stopTime=250 tolerance=1e-09 numberOfIntervals=2500 stepSize=0.1 Regular simulation: ./ThermoPower_ThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_C -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0137113s reading init.xml | | | | | | 0.0016901s reading info.xml | | | | | | 0.00014894s [ 0.0%] pre-initialization | | | | | | 0.0144707s [ 0.1%] initialization | | | | | | 0.00119383s [ 0.0%] steps | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.011368s [ 0.0%] event-handling | | | | | | 0.0435572s [ 0.2%] overhead | | | | | | 26.6619s [ 99.7%] simulation | | | | | | 26.7326s [100.0%] total | | | | | events | | | | | | 6 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 5584 steps taken | | | | | | 8013 calls of functionODE | | | | | | 968 evaluations of jacobian | | | | | | 374 error test failures | | | | | | 0 convergence test failures | | | | | | 12.7099s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.