Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.HeatTransfer.BaseClasses.test_ForcedConvection.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro_testsuite master/package.mo", uses=false) Using package TAeZoSysPro_testsuite with version (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro_testsuite master/package.mo) Using package TAeZoSysPro with version (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(TAeZoSysPro_testsuite.HeatTransfer.BaseClasses.test_ForcedConvection,tolerance=1e-06,outputFormat="empty",numberOfIntervals=20,variableFilter="",fileNamePrefix="TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.HeatTransfer.BaseClasses.test_ForcedConvection") translateModel(TAeZoSysPro_testsuite.HeatTransfer.BaseClasses.test_ForcedConvection,tolerance=1e-06,outputFormat="empty",numberOfIntervals=20,variableFilter="",fileNamePrefix="TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.HeatTransfer.BaseClasses.test_ForcedConvection") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001581/0.001581, allocations: 169.2 kB / 7.64 MB, free: 1.414 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.663/1.663, allocations: 205.3 MB / 213.4 MB, free: 13.76 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008825/0.0008824, allocations: 88.64 kB / 261.4 MB, free: 13.45 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/package.mo): time 0.06179/0.06179, allocations: 10.88 MB / 320.2 MB, free: 2.445 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro_testsuite master/package.mo): time 0.01688/0.01688, allocations: 4.166 MB / 374.5 MB, free: 79.23 MB / 298.7 MB Notification: Performance of FrontEnd - loaded program: time 2.351e-05/2.361e-05, allocations: 0 / 432.2 MB, free: 21.55 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1079/0.108, allocations: 50.76 MB / 483 MB, free: 2.699 MB / 330.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.8915/0.9995, allocations: 344.7 MB / 0.8083 GB, free: 2.027 MB / 458.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003152/0.9999, allocations: 68.78 kB / 0.8084 GB, free: 1.996 MB / 458.7 MB Error: Variable d in package TAeZoSysPro.HeatTransfer.BasesClasses.ForcedConvection$forcedConvection1 is not constant. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TAeZoSysPro master/HeatTransfer/BasesClasses/ForcedConvection.mo:48:3-48:14:writable] Error: Variable state.d not found in scope TAeZoSysPro.HeatTransfer.BasesClasses.ForcedConvection$forcedConvection1. Error: Error occurred while flattening model TAeZoSysPro_testsuite.HeatTransfer.BaseClasses.test_ForcedConvection Notification: Performance of FrontEnd: time 0.2657/1.266, allocations: 11.26 MB / 0.8194 GB, free: 174.5 MB / 458.7 MB