Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr SiemensPower_OMCtest_SiemensPower.Components.Valves.Tests.valve_test.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.1.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/package.mo", uses=false) Using package SiemensPower with version OMCtest (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/package.mo) Using package ModelicaServices with version 1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.0.0/package.mo) Using package Modelica with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.1.0+maint.om/package.mo) Running command: translateModel(SiemensPower.Components.Valves.Tests.valve_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="SiemensPower_OMCtest_SiemensPower.Components.Valves.Tests.valve_test") translateModel(SiemensPower.Components.Valves.Tests.valve_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="SiemensPower_OMCtest_SiemensPower.Components.Valves.Tests.valve_test") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.1.0+maint.om/package.mo): time 0.8918/0.8918, allocations: 110.8 MB / 118.3 MB, free: 10.57 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.0.0/package.mo): time 0.001658/0.001658, allocations: 155.4 kB / 144 MB, free: 9.812 MB / 122.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/package.mo): time 0.01967/0.01967, allocations: 3.969 MB / 173.5 MB, free: 12.24 MB / 154.7 MB Notification: Performance of FrontEnd - loaded program: time 1.572e-05/1.575e-05, allocations: 1.281 kB / 205 MB, free: 49.49 MB / 170.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.05865/0.05868, allocations: 26.1 MB / 231.1 MB, free: 26.94 MB / 170.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 5.241/5.3, allocations: 1.809 GB / 2.035 GB, free: 44.78 MB / 250.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000264/5.3, allocations: 55.22 kB / 2.035 GB, free: 44.73 MB / 250.7 MB Notification: Performance of FrontEnd - DAE generated: time 2.549/7.849, allocations: 0.584 GB / 2.619 GB, free: 9.852 MB / 266.7 MB Notification: Performance of FrontEnd: time 1.493e-06/7.849, allocations: 0 / 2.619 GB, free: 9.852 MB / 266.7 MB Notification: Performance of Transformations before backend: time 5.85e-05/7.849, allocations: 26.28 kB / 2.619 GB, free: 9.848 MB / 266.7 MB Error: Too few equations, under-determined system. The model has 237 equation(s) and 239 variable(s). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/Boundaries/GasSinkP.mo:24:3-28:24:writable] Warning: Variable gasSinkP.Xi_In[1] does not have any remaining equation to be solved in. The original equations were: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower OMCtest/Boundaries/GasSourceP.mo:31:3-35:24:writable] Warning: Variable gasSourceP.Xi_In[1] does not have any remaining equation to be solved in. The original equations were: