Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_PowerSystems.Examples.Wind.WindTurbine_PSGR.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo", uses=false) Using package PowerSystems with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Running command: translateModel(PowerSystems.Examples.Wind.WindTurbine_PSGR,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.Wind.WindTurbine_PSGR") translateModel(PowerSystems.Examples.Wind.WindTurbine_PSGR,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="PowerSystems_PowerSystems.Examples.Wind.WindTurbine_PSGR") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001083/0.001083, allocations: 183.7 kB / 8.354 MB, free: 0.7305 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.404/1.404, allocations: 194.3 MB / 203.1 MB, free: 13.02 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.00167/0.00167, allocations: 116 kB / 248.1 MB, free: 16 kB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo): time 0.1529/0.1529, allocations: 37.93 MB / 330.9 MB, free: 2.641 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 1.237e-05/1.24e-05, allocations: 4 kB / 390.4 MB, free: 7.086 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2779/0.2779, allocations: 53.22 MB / 443.6 MB, free: 17.77 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.459/0.737, allocations: 138.3 MB / 0.5682 GB, free: 30.13 MB / 378.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002569/0.7373, allocations: 86.45 kB / 0.5683 GB, free: 30.12 MB / 378.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.Wind.WindTurbine_PSGR Notification: Performance of FrontEnd: time 0.08067/0.818, allocations: 32.39 MB / 0.5999 GB, free: 12.7 MB / 378.7 MB