Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: translateModel(PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval") translateModel(PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001308/0.001307, allocations: 173.2 kB / 7.644 MB, free: 1.41 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.723/1.723, allocations: 205.3 MB / 213.4 MB, free: 13.75 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008934/0.0008933, allocations: 86.8 kB / 261.4 MB, free: 13.45 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.058/0.058, allocations: 14.02 MB / 323.4 MB, free: 15.34 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 2.369e-05/2.365e-05, allocations: 4 kB / 382.2 MB, free: 72.38 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1172/0.1172, allocations: 51.12 MB / 433.4 MB, free: 21.3 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4422/0.5595, allocations: 91.08 MB / 0.5122 GB, free: 10.57 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002808/0.5599, allocations: 72.38 kB / 0.5122 GB, free: 10.56 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval Notification: Performance of FrontEnd: time 0.01306/0.5729, allocations: 5.68 MB / 0.5178 GB, free: 8.281 MB / 330.7 MB