Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Ignoring simflag -noemit -homotopyOnFirstTry=() since it seems broken on HelloWorld Running command: translateModel(PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact") translateModel(PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002354/0.002354, allocations: 168.8 kB / 7.645 MB, free: 1.434 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.71/1.71, allocations: 205.3 MB / 213.4 MB, free: 1.738 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001059/0.001059, allocations: 86.23 kB / 261.4 MB, free: 1.684 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.05543/0.05543, allocations: 14.02 MB / 323.4 MB, free: 13.8 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 1.758e-05/1.759e-05, allocations: 4 kB / 381.5 MB, free: 3.574 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2983/0.2983, allocations: 51.12 MB / 432.6 MB, free: 16.11 MB / 282.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1378/0.4362, allocations: 89.84 MB / 0.5102 GB, free: 6.148 MB / 362.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003114/0.4366, allocations: 75.95 kB / 0.5102 GB, free: 6.074 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$bus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact Notification: Performance of FrontEnd: time 0.01427/0.4509, allocations: 5.571 MB / 0.5157 GB, free: 448 kB / 362.7 MB