Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneVariableLoad.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerGrids.Electrical.Test.OneBusImpedanceOneVariableLoad,tolerance=1e-06,outputFormat="empty",numberOfIntervals=600,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneVariableLoad") translateModel(PowerGrids.Electrical.Test.OneBusImpedanceOneVariableLoad,tolerance=1e-06,outputFormat="empty",numberOfIntervals=600,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneVariableLoad") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001342/0.001343, allocations: 171.4 kB / 7.641 MB, free: 1.414 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.772/1.772, allocations: 205.3 MB / 213.4 MB, free: 13.76 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009013/0.0009011, allocations: 89.36 kB / 261.4 MB, free: 13.45 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.0569/0.0569, allocations: 14.02 MB / 323.4 MB, free: 15.36 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 1.652e-05/1.654e-05, allocations: 0 / 380.7 MB, free: 73.94 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1123/0.1123, allocations: 51.11 MB / 431.8 MB, free: 22.86 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.378/0.4903, allocations: 82.74 MB / 0.5025 GB, free: 11.39 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002351/0.4906, allocations: 75.14 kB / 0.5026 GB, free: 11.39 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$bus1$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.OneBusImpedanceOneVariableLoad Notification: Performance of FrontEnd: time 0.01242/0.5031, allocations: 5.584 MB / 0.508 GB, free: 9.652 MB / 330.7 MB