Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneLoad.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: translateModel(PowerGrids.Electrical.Test.OneBusImpedanceOneLoad,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneLoad") translateModel(PowerGrids.Electrical.Test.OneBusImpedanceOneLoad,tolerance=1e-06,outputFormat="empty",numberOfIntervals=100,variableFilter="",fileNamePrefix="PowerGrids_PowerGrids.Electrical.Test.OneBusImpedanceOneLoad") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001078/0.001077, allocations: 169.2 kB / 7.64 MB, free: 1.414 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.75/1.75, allocations: 205.3 MB / 213.4 MB, free: 13.76 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.000986/0.000986, allocations: 89.45 kB / 261.4 MB, free: 13.45 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/package.mo): time 0.057/0.057, allocations: 14.03 MB / 323.4 MB, free: 15.35 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 2.053e-05/2.056e-05, allocations: 4 kB / 380.7 MB, free: 73.93 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1114/0.1114, allocations: 51.11 MB / 431.8 MB, free: 22.86 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3566/0.4681, allocations: 82.17 MB / 0.5019 GB, free: 11.37 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002183/0.4684, allocations: 77.39 kB / 0.502 GB, free: 11.37 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.OneBusImpedanceOneLoad Notification: Performance of FrontEnd: time 0.01602/0.4844, allocations: 7.725 MB / 0.5095 GB, free: 9.031 MB / 330.7 MB