Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IBPSA_latest_IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package IBPSA with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: translateModel(IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IBPSA_latest_IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator") translateModel(IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IBPSA_latest_IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0008757/0.0008756, allocations: 176.7 kB / 8.008 MB, free: 1.066 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo): time 0.4788/0.4788, allocations: 90.91 MB / 99.34 MB, free: 2.215 MB / 74.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.386/1.386, allocations: 221.5 MB / 343.2 MB, free: 1.605 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008543/0.0008542, allocations: 101.2 kB / 415.9 MB, free: 11.17 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 1.289e-05/1.292e-05, allocations: 4 kB / 494.5 MB, free: 52.41 MB / 362.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1237/0.1237, allocations: 72.31 MB / 0.5535 GB, free: 12.29 MB / 394.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 4.759/4.883, allocations: 2.207 GB / 2.76 GB, free: 207.3 MB / 0.6042 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001821/4.883, allocations: 97.66 kB / 2.76 GB, free: 207.2 MB / 0.6042 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: IBPSA.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type IBPSA.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class IBPSA.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope IBPSA.Fluid.Movers.Data.Generic (looking for a function or record). Error: Error occurred while flattening model IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator Notification: Performance of FrontEnd: time 3.236/8.119, allocations: 0.9535 GB / 3.714 GB, free: 88.59 MB / 0.6198 GB