Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier") translateModel(Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.797/1.797, allocations: 285.6 MB / 293.1 MB, free: 10.24 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001476/0.001476, allocations: 180.8 kB / 361.4 MB, free: 6.832 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.154/2.154, allocations: 205.2 MB / 0.62 GB, free: 11.66 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001198/0.001198, allocations: 96.39 kB / 0.733 GB, free: 44.2 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2e-05/2e-05, allocations: 0 / 0.8517 GB, free: 2.781 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7305/0.7306, allocations: 115.3 MB / 0.9643 GB, free: 78.75 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.993/6.723, allocations: 2.254 GB / 3.218 GB, free: 219.7 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000305/6.724, allocations: 86.45 kB / 3.219 GB, free: 219.6 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:249:11-249:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo1$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo1$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo1$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.RoomCapacityMultiplier Notification: Performance of FrontEnd: time 0.3608/7.085, allocations: 179.4 MB / 3.394 GB, free: 52.05 MB / 0.948 GB