startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./Buildings_maint.7.0.x_Buildings.Experimental.DistrictHeatingCooling.Plants.Validation.LakeWaterHeatExchanger_T_Heating -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.014072s reading init.xml | | | | | | 0.00175259s reading info.xml | | | | | | 0.00060744s [ 1.7%] pre-initialization | | | | | | 0.000268193s [ 0.8%] initialization | | | | | | 3.827e-06s [ 0.0%] steps | | | | | | 0.00159889s [ 4.5%] creating output-file | | | | | | 0.000438515s [ 1.2%] event-handling | | | | | | 0.0137505s [ 38.7%] overhead | | | | | | 0.0188379s [ 53.1%] simulation | | | | | | 0.0355053s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 293 steps taken | | | | | | 435 calls of functionODE | | | | | | 109 evaluations of jacobian | | | | | | 27 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000163052s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.