Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|noGai.bui.zon.TAir|radOnl.bui.zon.TAir|conOnl.bui.zon.TAir|latOnl.bui.zon.TAir|noGai.bui.zon.TRad|radOnl.bui.zon.TRad|conOnl.bui.zon.TRad|latOnl.bui.zon.TRad|noGai.bui.zon.phi|radOnl.bui.zon.phi|conOnl.bui.zon.phi|latOnl.bui.zon.phi|noGai.bui.zon.ports.1..Xi_outflow.1.|radOnl.bui.zon.ports.1..Xi_outflow.1.|conOnl.bui.zon.ports.1..Xi_outflow.1.|latOnl.bui.zon.ports.1..Xi_outflow.1.",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain") translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|noGai.bui.zon.TAir|radOnl.bui.zon.TAir|conOnl.bui.zon.TAir|latOnl.bui.zon.TAir|noGai.bui.zon.TRad|radOnl.bui.zon.TRad|conOnl.bui.zon.TRad|latOnl.bui.zon.TRad|noGai.bui.zon.phi|radOnl.bui.zon.phi|conOnl.bui.zon.phi|latOnl.bui.zon.phi|noGai.bui.zon.ports.1..Xi_outflow.1.|radOnl.bui.zon.ports.1..Xi_outflow.1.|conOnl.bui.zon.ports.1..Xi_outflow.1.|latOnl.bui.zon.ports.1..Xi_outflow.1.",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.339/2.339, allocations: 390.5 MB / 398 MB, free: 10.91 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001068/0.001068, allocations: 167.6 kB / 491.2 MB, free: 1.59 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.76/1.76, allocations: 221.5 MB / 0.7868 GB, free: 13.31 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001127/0.001127, allocations: 99.62 kB / 0.9269 GB, free: 13.8 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 1.978e-05/1.98e-05, allocations: 4 kB / 1.073 GB, free: 182 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3689/0.3689, allocations: 143 MB / 1.212 GB, free: 39.48 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.56/6.929, allocations: 1.959 GB / 3.171 GB, free: 310.2 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003106/6.93, allocations: 102.2 kB / 3.171 GB, free: 310.2 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/EnergyPlus_9_6_0/BaseClasses/ThermalZoneAdapter.mo:101:3-131:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain Notification: Performance of FrontEnd: time 1.699/8.629, allocations: 425.4 MB / 3.587 GB, free: 303.1 MB / 1.151 GB