startTime=0 stopTime=600 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.24 Regular simulation: ./Buildings_latest_Buildings.Fluid.Sources.Examples.TraceSubstancesFlowSource -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not C.warnAboutOnePortConnection assert | warning | Sensor TraceSubstancesFlowSource.C can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not C1.warnAboutOnePortConnection assert | warning | Sensor TraceSubstancesFlowSource.C1 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C1. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not C2.warnAboutOnePortConnection assert | warning | Sensor TraceSubstancesFlowSource.C2 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C2. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not C3.warnAboutOnePortConnection assert | warning | Sensor TraceSubstancesFlowSource.C3 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in TraceSubstancesFlowSource.C3. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0168229s reading init.xml | | | | | | 0.0014464s reading info.xml | | | | | | 0.000449874s [ 0.5%] pre-initialization | | | | | | 0.000369173s [ 0.4%] initialization | | | | | | 3.386e-06s [ 0.0%] steps | | | | | | 0.00191135s [ 2.2%] creating output-file | | | | | | 0.00011642s [ 0.1%] event-handling | | | | | | 0.0378943s [ 44.5%] overhead | | | | | | 0.0443327s [ 52.1%] simulation | | | | | | 0.0850772s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 124 steps taken | | | | | | 182 calls of functionODE | | | | | | 42 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 2 convergence test failures | | | | | | 0.000728166s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.