Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|sou.S.1.|sen.V|sen.I",fileNamePrefix="Buildings_latest_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented") translateModel(Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|sou.S.1.|sen.V|sen.I",fileNamePrefix="Buildings_latest_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.308/2.308, allocations: 390.5 MB / 398 MB, free: 10.93 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001336/0.001336, allocations: 172.2 kB / 491.2 MB, free: 1.629 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.701/1.701, allocations: 221.5 MB / 0.7868 GB, free: 13.29 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009543/0.0009542, allocations: 95.88 kB / 0.9269 GB, free: 13.78 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 2.903e-05/2.958e-05, allocations: 0 / 1.073 GB, free: 182.1 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3569/0.357, allocations: 143 MB / 1.212 GB, free: 39.58 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.695/5.052, allocations: 1.765 GB / 2.978 GB, free: 98.85 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002589/5.053, allocations: 99.94 kB / 2.978 GB, free: 98.75 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented Notification: Performance of FrontEnd: time 0.03376/5.087, allocations: 14.09 MB / 2.992 GB, free: 84.64 MB / 1.151 GB