Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine_N.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine_N,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|R1.load1.i.1.|R1.load1.i.2.|R2.load1.i.1.|R2.load1.i.2.|R3.load1.i.1.|R3.load1.i.2.",fileNamePrefix="Buildings_latest_Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine_N") translateModel(Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine_N,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|R1.load1.i.1.|R1.load1.i.2.|R2.load1.i.1.|R2.load1.i.2.|R3.load1.i.1.|R3.load1.i.2.",fileNamePrefix="Buildings_latest_Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine_N") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.227/2.227, allocations: 390.5 MB / 398 MB, free: 10.9 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001335/0.001335, allocations: 180.8 kB / 491.2 MB, free: 1.551 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.573/1.573, allocations: 221.5 MB / 0.7868 GB, free: 13.33 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008995/0.0008993, allocations: 95.88 kB / 0.9269 GB, free: 13.83 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 2.154e-05/2.137e-05, allocations: 4 kB / 1.073 GB, free: 182 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.307/0.3071, allocations: 143 MB / 1.212 GB, free: 39.52 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.084/1.391, allocations: 196.6 MB / 1.404 GB, free: 3.82 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003221/1.392, allocations: 96.59 kB / 1.404 GB, free: 3.77 MB / 0.823 GB Error: Error occurred while flattening model Buildings.Electrical.AC.ThreePhasesUnbalanced.Lines.Examples.ACLine_N Notification: Performance of FrontEnd: time 0.3083/1.7, allocations: 127.2 MB / 1.529 GB, free: 2.957 MB / 0.9323 GB