Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|grid.P.real|grid.P.apparent|pvSimple.load.S.1.|pvSimple.load.S.2.|RL.S.1.|RL.S.2.|pvOriented.panel.load.S.1.|pvOriented.panel.load.S.2.",fileNamePrefix="Buildings_latest_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels") translateModel(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|grid.P.real|grid.P.apparent|pvSimple.load.S.1.|pvSimple.load.S.2.|RL.S.1.|RL.S.2.|pvOriented.panel.load.S.1.|pvOriented.panel.load.S.2.",fileNamePrefix="Buildings_latest_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.184/2.184, allocations: 390.5 MB / 398 MB, free: 10.94 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001706/0.001705, allocations: 179.1 kB / 491.2 MB, free: 1.594 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.606/1.606, allocations: 221.5 MB / 0.7868 GB, free: 13.29 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001044/0.001044, allocations: 102 kB / 0.9269 GB, free: 13.79 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 1.85e-05/1.869e-05, allocations: 4 kB / 1.073 GB, free: 182.1 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3287/0.3288, allocations: 143 MB / 1.212 GB, free: 39.53 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.564/4.893, allocations: 1.765 GB / 2.977 GB, free: 74.84 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003562/4.894, allocations: 110 kB / 2.977 GB, free: 74.77 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.173/5.067, allocations: 72.55 MB / 3.048 GB, free: 5.777 MB / 1.151 GB