Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|grid.P.real|grid.P.apparent|pvSimple.load.S.1.|pvSimple.load.S.2.|RL.S.1.|RL.S.2.|pvOriented.panel.load.S.1.|pvOriented.panel.load.S.2.",fileNamePrefix="Buildings_latest_Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels") translateModel(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|grid.P.real|grid.P.apparent|pvSimple.load.S.1.|pvSimple.load.S.2.|RL.S.1.|RL.S.2.|pvOriented.panel.load.S.1.|pvOriented.panel.load.S.2.",fileNamePrefix="Buildings_latest_Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.267/2.267, allocations: 390.5 MB / 398 MB, free: 10.93 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001808/0.001807, allocations: 176.8 kB / 491.2 MB, free: 1.551 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.753/1.753, allocations: 221.5 MB / 0.7868 GB, free: 13.27 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008967/0.0008966, allocations: 91.88 kB / 0.9269 GB, free: 13.79 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 1.776e-05/1.781e-05, allocations: 4 kB / 1.073 GB, free: 182 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3027/0.3028, allocations: 143 MB / 1.212 GB, free: 39.52 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.331/4.634, allocations: 1.762 GB / 2.974 GB, free: 77.36 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003717/4.634, allocations: 97.34 kB / 2.974 GB, free: 77.31 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.1677/4.802, allocations: 70.46 MB / 3.043 GB, free: 10.6 MB / 1.151 GB