Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.MultipleBuildings.ThreeZonesTwoBuildings.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.MultipleBuildings.ThreeZonesTwoBuildings,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.MultipleBuildings.ThreeZonesTwoBuildings") translateModel(Buildings.ThermalZones.EnergyPlus.Validation.MultipleBuildings.ThreeZonesTwoBuildings,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.MultipleBuildings.ThreeZonesTwoBuildings") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.62/1.62, allocations: 289.9 MB / 297.4 MB, free: 6.352 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001441/0.001441, allocations: 172.9 kB / 366.7 MB, free: 1.637 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.693/1.693, allocations: 205.3 MB / 0.626 GB, free: 7.16 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009355/0.0009355, allocations: 100.3 kB / 0.74 GB, free: 39.52 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.705e-05/1.716e-05, allocations: 0 / 0.8597 GB, free: 13.07 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5806/0.5806, allocations: 116.3 MB / 0.9732 GB, free: 76.29 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.624/5.204, allocations: 2.119 GB / 3.092 GB, free: 281.9 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002532/5.205, allocations: 96.41 kB / 3.092 GB, free: 281.9 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.MultipleBuildings.ThreeZonesTwoBuildings Notification: Performance of FrontEnd: time 0.3148/5.519, allocations: 155.5 MB / 3.244 GB, free: 193.7 MB / 0.948 GB