Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer") translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.534/1.534, allocations: 289.9 MB / 297.4 MB, free: 6.426 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001004/0.001004, allocations: 180.8 kB / 366.7 MB, free: 1.715 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.481/1.481, allocations: 205.3 MB / 0.626 GB, free: 7.176 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.000916/0.0009161, allocations: 93.03 kB / 0.74 GB, free: 39.59 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.581e-05/1.594e-05, allocations: 4 kB / 0.8597 GB, free: 13.11 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5965/0.5965, allocations: 116.3 MB / 0.9733 GB, free: 76.29 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.143/5.739, allocations: 2.132 GB / 3.106 GB, free: 274.6 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002707/5.74, allocations: 99.75 kB / 3.106 GB, free: 274.6 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer Notification: Performance of FrontEnd: time 5.589/11.33, allocations: 1.613 GB / 4.719 GB, free: 115.4 MB / 0.9792 GB