Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF") translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.574/1.574, allocations: 289.9 MB / 297.4 MB, free: 6.391 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001065/0.001065, allocations: 180.8 kB / 366.7 MB, free: 1.676 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.497/1.497, allocations: 205.2 MB / 0.626 GB, free: 7.16 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008206/0.0008204, allocations: 93.92 kB / 0.74 GB, free: 39.54 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.777e-05/1.788e-05, allocations: 4 kB / 0.8597 GB, free: 13.04 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5951/0.5951, allocations: 116.3 MB / 0.9733 GB, free: 76.42 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.989/5.584, allocations: 2.243 GB / 3.216 GB, free: 193.4 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004253/5.584, allocations: 113.6 kB / 3.216 GB, free: 193.3 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF Notification: Performance of FrontEnd: time 1.877/7.461, allocations: 0.5234 GB / 3.74 GB, free: 39.72 MB / 0.948 GB