Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF") translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.642/1.642, allocations: 289.9 MB / 297.4 MB, free: 6.395 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001096/0.001096, allocations: 172.8 kB / 366.7 MB, free: 1.691 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.446/1.446, allocations: 205.2 MB / 0.626 GB, free: 7.203 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008346/0.0008344, allocations: 85.75 kB / 0.74 GB, free: 39.56 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.523e-05/1.526e-05, allocations: 4 kB / 0.8597 GB, free: 13.06 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6339/0.6339, allocations: 116.3 MB / 0.9733 GB, free: 76.4 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.985/5.619, allocations: 2.245 GB / 3.219 GB, free: 246.4 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003242/5.619, allocations: 116.8 kB / 3.219 GB, free: 246.3 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF Notification: Performance of FrontEnd: time 1.702/7.321, allocations: 0.5161 GB / 3.735 GB, free: 82.61 MB / 0.948 GB