Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF") translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.622/1.622, allocations: 289.9 MB / 297.4 MB, free: 6.352 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009734/0.0009735, allocations: 180.8 kB / 366.7 MB, free: 1.664 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.6/1.6, allocations: 205.3 MB / 0.626 GB, free: 7.176 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009945/0.0009946, allocations: 82.95 kB / 0.74 GB, free: 39.59 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.371e-05/2.381e-05, allocations: 4 kB / 0.8597 GB, free: 13.1 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6612/0.6612, allocations: 116.3 MB / 0.9733 GB, free: 76.29 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.869/5.53, allocations: 2.242 GB / 3.215 GB, free: 195.3 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004016/5.531, allocations: 114.3 kB / 3.215 GB, free: 195.2 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF Notification: Performance of FrontEnd: time 1.739/7.27, allocations: 0.5093 GB / 3.724 GB, free: 55.17 MB / 0.948 GB