Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop") translateModel(Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.541/1.541, allocations: 289.9 MB / 297.4 MB, free: 6.387 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001015/0.001015, allocations: 176.8 kB / 366.7 MB, free: 1.676 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.371/1.371, allocations: 205.3 MB / 0.626 GB, free: 7.164 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008765/0.0008765, allocations: 88.42 kB / 0.74 GB, free: 39.54 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.071e-05/2.08e-05, allocations: 4 kB / 0.8597 GB, free: 13.06 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6194/0.6195, allocations: 116.3 MB / 0.9732 GB, free: 76.39 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.9894/1.609, allocations: 459.5 MB / 1.422 GB, free: 93.4 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002518/1.609, allocations: 97.22 kB / 1.422 GB, free: 93.35 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Boilers/Examples/BoilerPolynomialClosedLoop.mo:11:3-21:72:writable] Error: component boi contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop Notification: Performance of FrontEnd: time 0.9174/2.527, allocations: 229.7 MB / 1.646 GB, free: 254.9 MB / 0.948 GB