Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring") translateModel(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.68/2.68, allocations: 285 MB / 292.5 MB, free: 10.54 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001395/0.001395, allocations: 188.8 kB / 360.7 MB, free: 7.23 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.011/2.011, allocations: 205.3 MB / 0.6192 GB, free: 12.14 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001326/0.001325, allocations: 101.1 kB / 0.7322 GB, free: 44.66 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.146e-05/2.152e-05, allocations: 0 / 0.8509 GB, free: 3.348 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8199/0.82, allocations: 115.3 MB / 0.9634 GB, free: 78.49 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.766/7.586, allocations: 2.131 GB / 3.095 GB, free: 285.3 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003475/7.587, allocations: 95.12 kB / 3.095 GB, free: 285.3 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring Notification: Performance of FrontEnd: time 8.318/15.9, allocations: 1.614 GB / 4.709 GB, free: 112.8 MB / 0.9792 GB