Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF") translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.598/2.598, allocations: 285 MB / 292.5 MB, free: 10.54 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001533/0.001533, allocations: 192.3 kB / 360.7 MB, free: 7.223 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.956/1.956, allocations: 205.3 MB / 0.6192 GB, free: 12.13 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001119/0.001119, allocations: 92.12 kB / 0.7322 GB, free: 44.69 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.217e-05/2.215e-05, allocations: 4 kB / 0.8509 GB, free: 3.355 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8492/0.8493, allocations: 115.2 MB / 0.9634 GB, free: 78.46 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.064/7.913, allocations: 2.237 GB / 3.2 GB, free: 239.4 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005068/7.914, allocations: 110.7 kB / 3.2 GB, free: 239.3 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:96:7-96:25:writable] Error: Component roo.datConExtWin[1].glaSys of variability PARAM has binding window600 of higher variability VAR. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF Notification: Performance of FrontEnd: time 2.086/10, allocations: 343.8 MB / 3.536 GB, free: 204 MB / 0.948 GB