Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide") translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.556/2.556, allocations: 285 MB / 292.5 MB, free: 10.48 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001527/0.001526, allocations: 192.8 kB / 360.8 MB, free: 7.254 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.962/1.962, allocations: 205.3 MB / 0.6192 GB, free: 12.16 MB / 474.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001085/0.001084, allocations: 97.97 kB / 0.7322 GB, free: 44.7 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.209e-05/2.207e-05, allocations: 4 kB / 0.8509 GB, free: 3.363 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8108/0.8108, allocations: 115.2 MB / 0.9634 GB, free: 78.76 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.413/2.224, allocations: 0.509 GB / 1.472 GB, free: 44.18 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004482/2.225, allocations: 105.7 kB / 1.473 GB, free: 44.12 MB / 0.8542 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Applications/DataCenters/ChillerCooled/Equipment/Validation/IntegratedPrimaryLoadSide.mo:47:3-49:73:writable] Notification: From here: [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Applications/DataCenters/ChillerCooled/Equipment/Validation/BaseClasses/PartialPlant.mo:65:3-67:73:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: Modelica.Blocks.Sources.BooleanStep onChi(startTime(displayUnit = "h") = 7200) "On and off signal for the chiller" second element is: .Modelica.Blocks.Sources.BooleanStep onChi(startTime = 7200) "On and off signal for the chiller" Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimaryLoadSide Notification: Performance of FrontEnd: time 0.1886/2.413, allocations: 54.53 MB / 1.526 GB, free: 1.473 MB / 0.8542 GB