Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.SingleZoneFloorWithHeating.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.SingleZoneFloorWithHeating,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.SingleZoneFloorWithHeating") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.281/2.281, allocations: 253.2 MB / 260.6 MB, free: 7.484 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001466/0.001466, allocations: 184.7 kB / 319.9 MB, free: 3.047 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.021/2.021, allocations: 205.6 MB / 0.5708 GB, free: 15.23 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001186/0.001186, allocations: 90.64 kB / 0.6751 GB, free: 4.598 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.702e-05/1.705e-05, allocations: 0 / 0.7849 GB, free: 102.2 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.22/0.2201, allocations: 106.3 MB / 0.8887 GB, free: 11.85 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.067/8.288, allocations: 2.428 GB / 3.317 GB, free: 202.5 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002698/8.288, allocations: 90.19 kB / 3.317 GB, free: 202.5 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Examples/VAVReheat/ThermalZones/Floor.mo:235:7-235:29:writable] Error: Type mismatch in binding material = Buildings.HeatTransfer.Data.Solids.Concrete$flo$matCon(0.1, 1.311, 836, 2240.0, 0.07627765064836003, 5, 2, false, 331.4, 119.5159318710878, 1.803197523703799, 293.15, 293.15, 0.0, false, false), expected subtype of record Buildings.HeatTransfer.Data.BaseClasses.Material Real(quantity = "Length", unit = "m") x; Real(quantity = "ThermalConductivity", unit = "W/(m.K)") k; Real(quantity = "SpecificHeatCapacity", unit = "J/(kg.K)") c; Real(quantity = "Density", unit = "kg/m3", displayUnit = "g/cm3", min = 0.0) d; Real(unit = "m2.K/W") R; Integer(min = 0) nStaRef; Integer(min = 1) nSta; Boolean steadyState; Real piRef; Real piMat; Real(min = 0.0) nStaReal; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") TSol; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") TLiq; Real(quantity = "SpecificEnergy", unit = "J/kg") LHea; Boolean ensureMonotonicity; Boolean phasechange; end Buildings.HeatTransfer.Data.BaseClasses.Material;, got type record Buildings.HeatTransfer.Data.Solids.Concrete$flo$matCon Real x; Real k; Integer c; Real d; Real R; Integer nStaRef; Integer nSta; Boolean steadyState; Real piRef; Real piMat; Real nStaReal; Real TSol; Real TLiq; Real LHea; Boolean ensureMonotonicity; Boolean phasechange; end Buildings.HeatTransfer.Data.Solids.Concrete$flo$matCon;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.SingleZoneFloorWithHeating Notification: Performance of FrontEnd: time 10.34/18.62, allocations: 1.931 GB / 5.248 GB, free: 44.41 MB / 0.948 GB