Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.497/2.497, allocations: 253.2 MB / 260.6 MB, free: 7.469 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001381/0.00138, allocations: 191.4 kB / 319.9 MB, free: 3.078 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.07/2.07, allocations: 205.6 MB / 0.5708 GB, free: 15.26 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001156/0.001156, allocations: 94.62 kB / 0.6751 GB, free: 4.613 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.859e-05/1.859e-05, allocations: 4 kB / 0.7849 GB, free: 102.2 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1999/0.1999, allocations: 106.3 MB / 0.8887 GB, free: 11.86 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.109/8.309, allocations: 2.366 GB / 3.255 GB, free: 212.6 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005653/8.31, allocations: 113.9 kB / 3.255 GB, free: 212.6 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:198:3-206:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900 Notification: Performance of FrontEnd: time 0.7863/9.096, allocations: 219 MB / 3.469 GB, free: 102.1 MB / 0.8698 GB