Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.171/2.171, allocations: 253.2 MB / 260.6 MB, free: 7.473 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001482/0.001482, allocations: 185.7 kB / 319.9 MB, free: 3.09 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.191/2.191, allocations: 205.6 MB / 0.5708 GB, free: 15.27 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00111/0.00111, allocations: 103.1 kB / 0.6751 GB, free: 4.629 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.227e-05/2.264e-05, allocations: 4 kB / 0.7849 GB, free: 102.2 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2085/0.2085, allocations: 106.3 MB / 0.8887 GB, free: 11.85 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.946/8.154, allocations: 2.365 GB / 3.254 GB, free: 212.3 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005502/8.155, allocations: 109.1 kB / 3.254 GB, free: 212.3 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:198:3-206:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650 Notification: Performance of FrontEnd: time 0.7577/8.913, allocations: 222.3 MB / 3.471 GB, free: 99.21 MB / 0.8698 GB