Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.38/2.38, allocations: 253.2 MB / 260.6 MB, free: 7.465 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001571/0.001571, allocations: 182.9 kB / 319.9 MB, free: 3.105 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.207/2.207, allocations: 205.6 MB / 0.5708 GB, free: 15.3 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001092/0.001091, allocations: 88.89 kB / 0.6751 GB, free: 4.664 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.869e-05/1.869e-05, allocations: 0 / 0.7849 GB, free: 102.2 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2039/0.204, allocations: 106.3 MB / 0.8887 GB, free: 11.89 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.963/2.167, allocations: 417.4 MB / 1.296 GB, free: 260.7 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002897/2.167, allocations: 90.28 kB / 1.296 GB, free: 260.7 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Chillers/Validation/CarnotVerifyCOP.mo:42:3-59:69:writable] Error: Variable chi_TEva: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi_TEva: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP Notification: Performance of FrontEnd: time 0.4614/2.628, allocations: 147.5 MB / 1.44 GB, free: 161.3 MB / 0.8698 GB