Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.808/2.808, allocations: 253.2 MB / 260.6 MB, free: 7.484 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002651/0.002651, allocations: 185.9 kB / 319.9 MB, free: 3.039 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.284/2.284, allocations: 205.6 MB / 0.5708 GB, free: 15.25 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001101/0.001101, allocations: 86.44 kB / 0.6751 GB, free: 4.605 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.241e-05/2.238e-05, allocations: 4 kB / 0.7849 GB, free: 102.2 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1949/0.195, allocations: 106.3 MB / 0.8887 GB, free: 11.84 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.31/7.505, allocations: 2.224 GB / 3.113 GB, free: 140.4 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003566/7.505, allocations: 99.56 kB / 3.113 GB, free: 140.4 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented Notification: Performance of FrontEnd: time 0.05031/7.556, allocations: 12.27 MB / 3.125 GB, free: 130 MB / 0.8698 GB