Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.26/2.26, allocations: 253.2 MB / 260.6 MB, free: 7.418 MB / 202.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001468/0.001467, allocations: 177.4 kB / 319.9 MB, free: 3.078 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.026/2.026, allocations: 205.6 MB / 0.5708 GB, free: 15.26 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001115/0.001115, allocations: 97.19 kB / 0.6751 GB, free: 4.613 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.738e-05/1.736e-05, allocations: 0 / 0.7849 GB, free: 102.2 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2106/0.2106, allocations: 106.3 MB / 0.8887 GB, free: 11.85 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.365/8.576, allocations: 2.663 GB / 3.551 GB, free: 17.16 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003376/8.576, allocations: 103.9 kB / 3.551 GB, free: 17.05 MB / 0.8698 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[2].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[1].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[2].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[1].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumSec[2].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumSec[1].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Examples/BaseClasses/PartialDataCenter.mo:121:5-121:17:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer Notification: Performance of FrontEnd: time 6.485/15.06, allocations: 1.101 GB / 4.653 GB, free: 96.86 MB / 0.9011 GB