Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Utilities.Plotters.Examples.SingleZoneVAV.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Utilities.Plotters.Examples.SingleZoneVAV,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Utilities.Plotters.Examples.SingleZoneVAV") Notification: Performance of loadModel(Buildings): time 4.221/4.221, allocations: 433.4 MB / 440.9 MB, free: 10.48 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 1.461e-05/1.469e-05, allocations: 3.938 kB / 0.5325 GB, free: 1.961 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6184/0.6184, allocations: 98.7 MB / 0.6289 GB, free: 15.73 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.992/7.61, allocations: 2.69 GB / 3.318 GB, free: 7.102 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002473/7.61, allocations: 91.95 kB / 3.319 GB, free: 7.012 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2331:7-2332:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooHea.getTableValueNoDer. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooHea.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooHea.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2331:7-2332:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooCoo.getTableValueNoDer. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooCoo.getTableTimeTmin. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$TSetRooCoo.getTableTimeTmax. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/Outside.mo:28:3-31:49:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource.mo:38:3-40:49:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg", final quantity = Medium.substanceNames) "Needed to connect to conditional connector" second element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg") "Needed to connect to conditional connector" Error: Error occurred while flattening model Buildings.Utilities.Plotters.Examples.SingleZoneVAV Notification: Performance of FrontEnd: time 1.055/8.666, allocations: 161.3 MB / 3.476 GB, free: 175.6 MB / 0.823 GB