Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindow.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindow") Notification: Performance of loadModel(Buildings): time 3.993/3.993, allocations: 433.4 MB / 440.9 MB, free: 10.47 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.22e-05/2.232e-05, allocations: 4 kB / 0.5325 GB, free: 1.945 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5079/0.508, allocations: 98.71 MB / 0.6289 GB, free: 15.74 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.806/6.314, allocations: 2.326 GB / 2.955 GB, free: 98.55 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002655/6.314, allocations: 103.9 kB / 2.955 GB, free: 98.45 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindow Notification: Performance of FrontEnd: time 1.956/8.27, allocations: 414.6 MB / 3.36 GB, free: 10.68 MB / 0.823 GB